• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPLACING FUSES
FUSE (BLADE-TYPE) COLOR CODES

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  696    697    698    699    700  701  702    703    704    705    706  
img
TM 5-3805-280-24-2
Wiring Harness and Switches
IMPORTANT: Install fuse with correct amperage
rating to prevent electrical system
damage from overload.
1--5 Amp Backup
2--10 Amp Controller
3--10 Amp EC Motor
4--5 Amp Solenoid
5--10 Amp Power On
6--5 Amp Switch Box
7--5 Amp Option 1
8--10 Amp Option 2
9--5 Amp Option 3
10--5 Amp Travel (Alarm)
11--20 Amp Lamp
12--10 Amp Wiper (Windshield and Washer)
13--20 Amp Heater
14--5 Amp AirCon (Air Conditioning)
15--10 Amp Horn
16--5 Amp Radio
17--10 Amp Lighter
16
18--5 Amp Room Lamp (Dome Light)
1674
19--10 Amp Auxiliary
11
20--20 Amp Start Aid
TX,16,UU3961
1919SEP982/2
16-42


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.