• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REMOVE AND INSTALL COOLANT LEVEL SWITCH
REMOVE AND INSTALL FUEL LEVEL SWITCH

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  704    705    706    707    708  709  710    711    712    713    714  
img
TM 5-3805-280-24-2
Wiring Harness and Switches
REMOVE AND INSTALL ENGINE OIL LEVEL
SWITCH
1. Disconnect connector and remove cap screws to
remove and replace switch (A).
2. Install switch (A) and tighten cap screws. Connect
connector.
A--Switch
TX,16,UU3970
1919SEP981/1
REMOVE AND INSTALL ENGINE COOLANT
TEMPERATURE SENSOR
1. Disconnect connector to remove and replace sensor
(A).
16
1674
2. Install and tighten sensor (A) and connect connector.
19
A--Sensor
TX,16,UU3566
1919SEP981/1