REMOVE AND INSTALL HOUR METER
REMOVE AND INSTALL BATTERY RELAY

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  717    718    719    720    721  722  723    724    725    726    727  
img
TM 5-3805-280-24-2
Wiring Harness and Switches
DISCONNECTING SPRING WIRE RETAINER
CONNECTORS
1. Grasp connector halves; move half of connector from
side-to-side as it's being pulled apart. Wire retainer will
slide over retaining tabs. Do not pull on wiring leads.
2. To reconnect, push together until wire retainer "clicks"
over tabs.
TX,16,UU3988
1918JUL941/1
DISCONNECTING TAB RETAINER
CONNECTORS
IMPORTANT: Do not disconnect electrical connectors
while the engine is running. Damage to
16
engine and pump controller or other
1674
components may result. Disconnect
32
connectors only when instructed during
a test or check.
1. Push retainer tab (A).
2. Hold tab and pull connector halves apart; do not pull
A--Retainer Tab
on wiring leads.
TX,16,UU3308
1919SEP981/1