REMOVE AND INSTALL BATTERY RELAY
REMOVE AND INSTALL FUEL SHUTOFF RELAY

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  719    720    721    722    723  724  725    726    727    728    729  
img
TM 5-3805-280-24-2
Wiring Harness and Switches
REMOVE AND INSTALL STARTER RELAY
1. Disconnect battery ground cable.
2. Disconnect wiring leads (D--F).
3. Remove cap screws and washers (C) to remove starter
relay (A).
4. Install relay. Connect wiring leads.
16
A--Starter Relay
1674
B--Fuel Shutoff Relay
34
C--Cap Screw and Washer (2 used)
D--Wiring Lead
E--Wiring Lead
F--Wiring Lead