REMOVE AND INSTALL OVERLOAD ALARM
PROXIMITY SWITCH
1. Operate excavator to place boom on side of excavator
(cab perpendicular to tracks).
2. Turn excavator Off.
3. Disconnect connector (A).
4. Remove nuts (B) and proximity switch (D). Replace
parts as necessary.
5. Adjust gap (C) to 6.5--9.5 mm (1/4--3/8 in.).
16
A--Connector
1674
B--Nut (2 used)
39
C--Gap 6.5--9.5 mm (1/4--3/8 in.)
D--Proximity Switch
CED,OUOE020,60 1925MAY991/1