ARMATURE--REMOVAL
TURNING COMMUTATOR DOWN

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  745    746    747    748    749  750  751    752    753    754    755  
img
TM 5-3805-280-24-2
Robert Bosch Starting Motor Repair
TESTING ARMATURE FOR SHORT CIRCUIT
Place armature in a growler and hold hacksaw blade
above each slot while slowly rotating the armature.
60
If coil is shorted, the blade will be attracted to and
10
repelled from the slot.
9
Short circuit most often occurs because of copper dust or
filings between two commutator segments. Clean
commutator segments to correct this short.
RG,RG34710,2351 1915Mar971/1
TESTING ARMATURE FOR OPEN CIRCUIT
Set ohmmeter to read on lowest scale.
Place one test lead on commutator segment. Place other
test lead on an adjacent segment. Repeat this operation
for all segments by moving one lead at a time.
If the test meter indicator does not swing to zero and
remains stationary, the armature coil between these two
segments is open. Replace armature.
RG,RG34710,2352 1915Mar971/1