REMOVE AND INSTALL DIG FUNCTION PILOT CONTROLLER - Continued
DISASSEMBLE AND ASSEMBLE DIG FUNCTION PILOT CONTROLLER

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  965    966    967    968    969  970  971    972    973    974    975  
img
TM 5-3805-280-24-2
Hydraulic System
6. Remove screws (M) to disconnect hose boot (N) from
console.
7. Remove cap screws (O) to remove pilot controller (P)
from console.
M--Screws
N--Hose Boot
O--Cap Screw
P--Pilot Controller
TX,33,UU4000
1921SEP984/5
8. Disconnect lines (P, T and 1--4) from pilot controller.
Identify the lines by the numbers and letters stamped
on the controller housing.
Install caps and plugs to close all openings.
9. After pilot controller is installed, check the operation of
all functions to be sure they operate as shown on the
decal on console.
33
3360
P--Hydraulic Line
71
T--Hydraulic Line
1--Hydraulic Line
2--Hydraulic Line
3--Hydraulic Line
4--Hydraulic Line
TX,33,UU4000
1921SEP985/5
21-108