TM 5-3805-280-24-2
Rock Drill
44
9506
159
1--Pressure Sensor Switch
6--Adapter
11--Locknut (2 used)
16--Valve
2--Hose (4 used)
7--Adapter (2 used)
12--Air Flow Detector
17--Valve Seat
3--Adapter
8--Nipple (2 used)
13--Rush
4--Restrictor Adapter
9--Adapter
14--Valve Guide
5--Adapter
10--Screw (2 used)
15--Spring
179. Install four hoses (2).
175. Install valve (16), spring (15), valve guide (14),
and rush (13).
180. Install pressure sensor switch (1),
176. Install air flow detector (12), two screws (10), and
181. Remove tags and connect wires to pressure
locknuts (11).
sensor switch (1).
177. Install adapter (9), two nipples (8), and two
adapters (7).
178. Install adapters (5 and 6), restrictor adapter (4),
and adapter (3).
Continued on next page
CED,OUOE019,18 1901APR9938/49
23-148