REPLACE FINAL FUEL FILTER
CHECK AIR INTAKE HOSES

Operator Manual For Hydraulic Excavator Model 330Lcr
Page Navigation
  194    195    196    197    198  199  200    201    202    203    204  
img
.
TM 5-3805-281-10
Maintenance--Every 500 Hours
REPLACE PRIMARY FUEL FILTER (WATER
SEPARATOR)
1. Turn retaining ring (A) counterclockwise to remove filter
(B). Allow sediment to drain into a container. Dispose
of waste properly.
2. Turn sediment bowl (C) counterclockwise to remove
from filter assembly. Clean bowl.
3. Remove hand primer from fuel filter base. Disassemble
hand primer assembly.
A--Retaining Ring
B--Filter
C--Sediment Bowl
Continued on next page
TX,80,DH5123