TM 5-3805-281-10
Maintenance
REPLACING BATTERIES
Your machine has two 12 volt batteries with negative (-)
ground. Batteries must meet one of the specifications
below.
Battery--Specification
Cold Cranking Amps At -18C ........................................................... 1400
(0F)
Minutes Reserve Capacity At 25 ......................................................... 440
Amps
If one battery in a 24-volt system has failed but the other
is still good, replace the failed battery with one of the
same type. For example, replace a failed
maintenance-free battery with a new maintenance-free
battery. Different types of batteries may have different
rates of charge. This difference could overload one of the
batteries and cause it to fail.
CED,OUOE020,49 1913APR991/1
REMOVING BATTERIES
1. Remove two wing nuts from battery cover.
2. Disconnect negative (-) battery cables first, then
positive (+) cables.
3. Remove hold down brackets.
4. Lift batteries out of compartment.
TX,90,DH5154
1910AUG961/1