REPLACING FUSES
REMOVING THE BUCKET

Operator Manual For Hydraulic Excavator Model 330Lcr
Page Navigation
  236    237    238    239    240  241  242    243    244    245    246  
img
.
TM 5-3805-281-10
Maintenance
FUSE (BLADE-TYPE) COLOR CODES
Amperage Rating
Color
1
Black
3
Violet
4
Pink
5
Tan
7-1/2
Brown
10
Red
15
Light Blue
20
Yellow
25
Natural (White)
30
Light Green
04T,90,J22 1928SEP921/1
CHECKING TRAVEL ALARM SYSTEM
1. Propel machine forward.
Travel alarm must sound.
2. Stop machine.
Travel alarm must stop.
3. Propel machine forward.
4. Depress travel alarm cancel switch (A).
A--Travel Alarm Cancel Switch
After an initial 12 second alarm, alarm must stop.
5. Repeat test with machine traveling in reverse.
6. If the travel alarm does not operate properly, do not
operate machine. See your authorized dealer.
TX,90,DH5141
1908AUG961/1
18-16