Operational Checkout Procedure - Continued
Operational Checkout Procedure - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  42    43    44    45    46  47  48    49    50    51    52  
img
TM 5-3805-281-24-1
Operational Checkout Procedure
HP (HIGH POWER)
YES: Go to next check.
MODE CHECK
NO: Check switch,
indicator, arm in sensor,
pump pressure sensor,
and harness. Go to
9005
Group 9015-15.
10
9
Check linkage and fast
T111983 UN27OCT97
T112183 UN13NOV97
idle speed stop at the
injection pump. Go to
A--HP (High Power) Mode Switch
Group 9010-20.
B--HP (High Power) Mode Indicator
Start the engine.
Auto-idle switch OFF.
Turn engine rpm dial clockwise to fast idle.
Push HP (High Power) mode switch (A) on.
Does HP (High Power) mode indicator (B) come on?
Operate the arm in function over relief (arm cylinder fully extended).
Does engine speed increase?
Push HP mode switch again to turn it OFF.
Does HP mode indicator go out?
1/1