• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
POWER CIRCUIT DIAGNOSTIC PROCEDURES - Continued
CHARGING CIRCUIT THEORY OF OPERATION

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  207    208    209    210    211  212  213    214    215    216    217  
img
TM 5-3805-281-24-1
Sub-System Diagnostics
FUSE CHECK
YES: Fuse is OK
NO: Replace fuse.
T7468AF UN14MAR91
9015
Remove cover from fuse block.
15
7
Turn key switch ON.
Connect black (-) probe of multimeter to screw head (ground) in console.
Set multimeter to measure 24 volts.
Connect multimeter red (+) probe to the outside slot in each fuse.
Is 24 volts measured on each fuse?
1/1
4-75


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.