TM 5-3805-281-24-1
Tests
3. Connect flow meter in series with pilot pressure inlet
line (A) at pilot filter (B). Open the flow meter loading
valve.
Electronic Tachometer Installation in this group.)
5. Install the temperature probe on the hydraulic
tank-to-pump suction line. (See JT05800 Digital
Thermometer Installation in this group.)
6. Heat hydraulic oil to the specified temperature. (See
Hydraulic System Warm-Up Procedure in this group.)
Hydraulic Oil--Specification
Temperature ........................................................... 50 5C (120 10F)
NOTE: The pilot pressure regulating valve will regulate
pump discharge pressure. It is not necessary to
load the pump using flow meter loading valve.
7. Run engine at test specifications.
Engine--Specification
Speed ................................................................................... 2000 10 rpm
9025
A--Pilot Pressure Inlet Line (3/4-16 F 37 Sw
Work Mode Selector--Specification
25
Fitting)
129
Position ........................................................................................ Dig Mode
B--Pilot Filter
E Mode Switch--Specification
Position .................................................................................................. Off
HP Mode Switch--Specification
Position .................................................................................................. Off
Auto-Idle Switch--Specification
Position .................................................................................................. Off
8. Record flow meter reading.
Pilot Pump--Specification
Flow Rate .................................................. 25.0 L/Min (6.6 gpm) minimum
flow at 3925 kPa (39 bar) (570
psi)
Continued on next page
CED,TX08227,3145
1929MAY983/4
6-276