TM 5-3805-281-24-1
Adjustments
RECOVER R134A SYSTEM
ESSENTIAL TOOLS
JT02045 R134a Refrigerant Recovery/Recycling and Charging Station
JT02046 R134a Refrigerant Recovery/Recycling and Charging Station
(Alternate)
JT02050 R134a Refrigerant Recovery/Recycling and Charging Station
(Alternate)
CAUTION: Do not remove high pressure relief
valve (H). Air conditioning system will
discharge rapidly causing possible injury.
IMPORTANT: Use correct refrigerant recovery,
recycling and charging stations. DO
NOT mix refrigerant, hoses, fittings,
components or refrigerant oils.
A--High Pressure Test Port
B--Blue Hose
NOTE: JT02046 and JT02050 recovery and charging
C--Red Hose
stations can be substituted for the JT02045
D--High Pressure Hose
station.
E--Low Pressure Hose
F--Low Pressure Test Port
G--Refrigerant Recovery/Recycling and Charging
1. Run the air conditioning system for three minutes to
Station
help in the recovery process. Turn air conditioning
H--High Pressure Relief Valve
system off before proceeding with recovery steps.
2. Connect refrigerant recovery, recycling and charging
station. (See installation procedure in this group.)
3. Follow the manufacturer's instructions when using the
refrigerant recovery, recycling and charging station.
9031
20
6
CED,TX14795,4340
1904MAR981/1