REPAIR IN-LINE FUEL INJECTION PUMP - Continued
INSTALL WATER PUMP

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  17    18    19    20    21  22  23    24    25    26    27  
img
TM 5-3805-281-24-2
Removal and Installation
NOTE: The water pump should be replaced as a
complete assembly
CAUTION: Explosive release of fluids from
pressurized cooling system can cause serious
burns. Wait until engine coolant is cool enough
to touch with bare hands before draining.
Slowly loosen radiator cap to first stop to
relieve pressure.
6. Open water pump drain valve (A) and block drain valve
(B) to drain coolant from engine.
04
0400
21
A--Water Pump Drain Valve
B--Cylinder Block Drain Valve
CED,OUOE024,204
1914MAY983/5
7. Remove six cap screws securing water pump cover (A)
to timing gear cover and remove water pump cover
with bypass tube (B).
8. Remove gasket from timing gear cover and discard.
Remove bypass tube from cover. Inspect bypass tube
seal in water pump cover, replace seal as needed.
A--Water Pump Cover
B--Bypass Tube
Continued on next page
CED,OUOE024,204
1914MAY984/5
11-21