ROBERT BOSCH STARTING MOTOR SPECIFICATIONS
DIAGNOSING STARTING MOTOR MALFUNCTIONS

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  560    561    562    563    564  565  566    567    568    569    570  
img
.
TM 5-3805-281-24-2
Robert Bosch Starting Motor Repair
MAKE NO-LOAD TEST
1. Make connections as shown, and use an ammeter (A)
capable of measuring several hundred amps.
60
2. Measure current draw in amps and compare with
10
specifications given earlier in this group.
3
3. If speed and current draw are slightly low, connect a
voltmeter between motor terminal and frame. Observe
voltage during test. Voltage may be reduced because
of high current draw on battery.
A--Ammeter
4. If speed or current draw is significantly different than
B--Battery
specified, diagnose problem per chart which follows.
C--Starter Frame
D--Tachometer
E--Battery Terminal
F--Switch
G--Field Coil Connector
RG,RG34710,2340 1915MAR971/1