• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REPLACE MONITOR PANEL AND SWITCH PANEL BULB - Continued
Starting Motors

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  555    556    557    558    559  560  561    562    563    564    565  
img
.
TM 5-3805-281-24-2
Instruments and Indicators
REMOVE AND INSTALL HOUR METER
1. Remove bottom panel.
2. Remove connector (C).
3. Remove screws (A and B). Remove hour meter.
4. Repair or replace parts as required.
5. Install hour meter.
6. Install bottom panel.
A--Screw
B--Screw
C--Connector
TX,16,UU3327
1911JUL921/1
CHANGING PROPEL ALARM VOLUME
IMPORTANT: It may be necessary to adjust propel
alarm volume to meet local regulations.
NOTE: Alarm removed from machine for clarity.
1. Remove four sheet metal screws to remove propel
alarm front cover.
NOTE: This machine is shipped with the propel alarm set
in the "High" position.
A--Volume Level
2. Adjust volume level of propel alarm by connecting
metallic bar to appropriate terminals. The alarm can be
set at "LOW", "MED" (medium), or "HIGH" volume
levels.
16
1676
3
3. Install front cover.
CED,OUOE042,232 1912MAR981/1
15-66


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.