TM 5-3805-281-24-2
System Controls
REMOVE AND INSTALL ENGINE AND PUMP
CONTROLLER (EPC)
IMPORTANT: If a controller problem is indicated, the
real problem may be poor connector pin
contact. Before replacing controller,
remove and install controller
connectors. Check machine operation.
1. Disconnect battery ground cable.
2. Move seat forward and remove access cover.
3. Disconnect cable connectors (D--F).
5. Remove cap screws (C) and remove cover (B).
6. Remove screws (G).
7. Install engine and pump controller.
8. Do engine speed learning procedure. (See procedure
in this group.)
A--Electrical Connector (2 used)
B--Cover
C--Cap Screw (4 used)
D--EPC Connector
E--EPC Connector
F--EPC Connector
G--Screw (4 used)
16
1675
6
CED,OUOE003,1158
1907JUL981/1