TM 5-3805-281-24-2
RECOVER R134A SYSTEM
CAUTION: Do not remove high pressure relief
valve (B). Air conditioning system will
discharge rapidly causing possible injury.
IMPORTANT: Use correct refrigerant recovery,
recycling and charging stations. DO
NOT mix refrigerant, hoses, fittings,
components or refrigerant oils.
NOTE: Run the air conditioning system for three minutes
to help in the recovery process. Turn air
conditioning system off before proceeding with
recovery steps.
1. Connect refrigerant recovery, recycling and charging
station. (See installation procedure in this group.)
2. Follow the manufacturer's instructions when using the
refrigerant recovery, recycling and charging station.
A--Low Pressure Test Port
B--High Pressure Relief Valve
C--Low Pressure Hose
D--Low Pressure Switch
E--High Pressure Switch
F--High Pressure Quick-Disconnect
G--Blue Hose
H--High Pressure Hose
I--Red Hose
J--Refrigerant Recovery/Recycling and Charging
Station
CED,OUOE027,285
1929MAY981/1
18
1830
10