REMOVE AND INSTALL HYDRAULIC PUMP - Continued
HYDRAULIC PUMP AND SPLITTER DRIVE START-UP PROCEDURE

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  704    705    706    707    708  709  710    711    712    713    714  
img
TM 5-3805-281-24-2
Hydraulic System
CAUTION: The approximate weight of hydraulic
pump is 68 kg (150 lb).
33
3360
Hydraulic Pump--Specification
22
Weight.............................................................. 68 kg (150 lb) approximate
6. Install M12-1.75 metric lifting eyebolt, such as JT05550
Metric Lifting Eyebolts, in tapped holes in air bleed
plug (D). Connect a hoist and lifting bracket to eyebolt.
7. Remove pump-to-splitter drive cap screws (I) to
remove pump. Repair or replace pump as necessary.
8. Install pump.
9. Tighten pump-to-splitter drive cap screws (I).
Pump-to-Splitter Drive Cap Screw--Specification
Torque ............................................................................. 49 Nm (36 lb-ft)
10. Connect hydraulic lines.
11. Install elbows (A and J) and cap screws (K).
12. Apply pipe sealant to drain plug threads.
IMPORTANT: Hydraulic pump and splitter drive will
be damaged if not filled with oil before
starting engine. Procedure must be
performed whenever a new pump or
splitter drive is installed or oil has been
drained from the pump, splitter drive or
hydraulic oil tank.
13. Fill pump housing and splitter drive with oil. (See
Hydraulic Pump and Splitter Drive Start-Up Procedure
in this group.)
14. Check pump regulator adjustments. (See Hydraulic
Pump Regulator Test and Adjustments in Group
9025-25.)
CED,OUOE027,295
1903JUN983/3
19-62