HYDRAULIC OIL CLEANUP PROCEDURE USING PORTABLE FILTER CADDY
REMOVE AND INSTALL HYDRAULIC PUMP - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  702    703    704    705    706  707  708    709    710    711    712  
img
.
TM 5-3805-281-24-2
Hydraulic System
REMOVE AND INSTALL HYDRAULIC PUMP
33
CAUTION: The hydraulic oil tank is pressurized.
3360
High pressure release of oil from pressurized
20
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
NOTE: Procedure is the same for front or rear pumps.
1. Loosen vent plug (A) to release air pressure in
hydraulic oil tank.
A--Vent Plug
2. Drain hydraulic oil tank. Approximate oil capacity is 159
L (42 gal).
3. Drain splitter drive. Approximate oil capacity is 1.0 L
(1.06 qt).
Continued on next page
CED,OUOE027,295
1903JUN981/3