TM 5-3805-294-10
0004
Table 4.
Left Console and Pilot Shutoff Lever.
24
26
28
25
27
HYEX00870
Figure 7. Left Console and Pilot Shutoff Lever.
Key
Control/Indicator
Function
24
Pilot Shutoff Lever
Controls hydraulic functions on the machine. With the lever in the locked
position, hydraulic functions are not operational. In the unlocked position, all
hydraulic functions operate. The engine will not start with the lever in the
unlocked position.
25
Travel Alarm Switch
After the initial 13-second alarm, depressing the right half of the switch will shut
the alarm off.
26
Rear Cab Work
Turns the rear cab work lights on and off.
Lights Switch
27
Auxiliary Control
Disables the right joystick left and right button auxiliary function.
Switch
28
Reversing Cooling
This is a three position switch that controls the direction that the cooling fan is
Fan Switch
moving. AUTO: Every 60 minutes the cooling fan will automatically reverse
direction for 15 seconds without intervention from the operator. OFF Fan
resumes normal operation. MANUAL: Fan will reverse direction for 15 seconds