Table 1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Continued
Figure 3. Coolant Level.

Operators Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch Page Navigation
  280    281    282    283    284  285  286    287    288    289    290  
img
.
TM 5-3805-294-10
0077
Table 1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Continued
EQUIPMENT NOT
ITEM TO BE CHECKED
READY/
ITEM
INTERVAL
OR SERVICED
PROCEDURE
AVAILABLE IF:
NO.
2
Before
Left and Right Track
Check for loose or missing track
Loose or miss-
Chain and Rollers
shoe (Figure 2, Item 2) and track
ing track shoe.
bolts.
One or more
bolts missing
from track shoe.
3
1
4
2
HYEX01001
Figure 2. Exterior of Machine Continued.
Check for oil leakage from carrier
Oil leaking from
roller (Figure 2, Item 3) or support
carrier roller or
rollers (Figure 2, Item 4).
support roller.
3
Before
Coolant Surge Tank
Check that coolant is at the MIN
Coolant level
COLD line (Figure 3, Item 5) on the
below MIN
surge tank (Figure 3, Item 6).
COLD level.
0077-4