TM 5-3805-294-10
0077
Table 1.
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Continued
EQUIPMENT NOT
ITEM TO BE CHECKED
READY/
ITEM
INTERVAL
OR SERVICED
PROCEDURE
AVAILABLE IF:
NO.
WARNING
17
Before
Batteries
LEAD-ACID BATTERIES
Remove four wing nuts (Figure 13,
Item 34), washers (Figure 13, Item
35), and two covers (Figure 13,
Item 36) from batteries (Figure 13,
Item 37).
Check batteries (Figure 13, Item
Batteries show
37) for leaks or cracks.
signs of leaking
or have cracks.
40
41
36
34, 35
37
38
39
HYEX01011
Figure 13. Batteries.
Check battery cables (Figure 13,
Battery cables
Item 38) for looseness.
are loose.
Install two covers (Figure 13, Item
36) to batteries (Figure 13, Item 37)
with four wing nuts (Figure 13, Item