Table 1. DTC 651.02 - Injector #1 Part Number Invalid - Continued
DTC 651.05 - INJECTOR #1 CIRCUIT HAS HIGH RESISTANCE

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  451    452    453    454    455  456  457    458    459    460    461  
img
TM 5-3805-294-23-1
0065
Table 1. DTC 651.02 - Injector #1 Part Number Invalid - Continued.
Test or Inspection
Corrective Action
Malfunction
15.
After Calibration Complete
appears, select OK. (Volume
3, WP 0340)
16.
Select Exit and then select
Yes. (Volume 3, WP 0340)
17.
Select Reading and select
Disconnect From Model(s).
(Volume 3, WP 0340)
18.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
19.
Turn key switch to OFF
position for a minimum of 90
seconds to complete the
calibration. (TM
5-3805-294-10). (Volume 5,
WP 0794)
20.
Clear and refresh DTCs. Note
1.
If DTC 651.02 is still an active
if DTC 651.02 is still an active
DTC, it is possible that another
fault exists or that another
DTC. (Volume 3, WP 0362)
troubleshooting procedure
applies. If this was the first time
through this procedure, restart
procedure at Malfunction 1.
2.
If DTC 651.02 is not an active
DTC, problem corrected.
END OF WORK PACKAGE