• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 651.13 - Injector #1 Calibration Fault - Continued.
Table 1. DTC 651.13 - Injector #1 Calibration Fault - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  472    473    474    475    476  477  478    479    480    481    482  
img
TM 5-3805-294-23-1
0069
Table 1. DTC 651.13 - Injector #1 Calibration Fault - Continued.
Test or Inspection
Corrective Action
Malfunction
15.
After Calibration Complete
appears, select OK. (Volume
3, WP 0340)
16.
Select Exit and then select
Yes. (Volume 3, WP 0340)
17.
Select Reading and select
Disconnect From Model(s).
(Volume 3, WP 0340)
18.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
19.
Turn key switch to OFF
position for a minimum of 90
seconds to complete the
calibration. (TM
5-3805-294-10). (Volume 5,
WP 0794)
20.
Clear and refresh DTCs. Note
1.
If DTC 651.13 is still an active
if DTC 651.13 is still an active
DTC, proceed to Malfunction
4.
DTC. (Volume 3, WP 0362)
2.
If DTC 651.13 is not an active
DTC, problem corrected.
1.
Replace ECU. (Volume 4,
4.
ECU Faulty.
WP 0508)
2.
Turn key switch to ON position,
but DO NOT START ENGINE
(TM 5-3805-294-10). (Volume
5, WP 0794).
3.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0340)
4.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0340)
5.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0340)
0069-7