Table 1. DTC 651.13 - Injector #1 Calibration Fault.
Table 1. DTC 651.13 - Injector #1 Calibration Fault - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
img
TM 5-3805-294-23-1
0069
Table 1. DTC 651.13 - Injector #1 Calibration Fault - Continued.
Test or Inspection
Corrective Action
Malfunction
11.
Select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0340)
12.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
13.
Turn key switch to OFF
1.
If calibration codes are the
position (TM 5-3805-294-10).
same, proceed to Malfunction
2.
(Volume 5, WP 0794)
2.
If calibration codes are not the
same, proceed to Malfunction
3.
1.
Replace ECU. (Volume 4,
2.
ECU Faulty.
WP 0508)
2.
Turn key switch to ON position,
but DO NOT START ENGINE
(TM 5-3805-294-10). (Volume
5, WP 0794).
3.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0340)
4.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0340)
5.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0340)
6.
Select Tests and Calibrations
tab in Service ADVISOR and
select 240DLCR - Excavator -
None. (Volume 3, WP 0340)
7.
Select Connected Calibrations
and select Interactive
Calibrations. (Volume 3,
WP 0340)
8.
Under Interactive Calibrations,
select ECU - (shown with
engine serial number).
(Volume 3, WP 0340)