TM 5-3805-294-23-1
0074
Table 1. DTC 652.13 - Injector #2 Calibration Fault - Continued.
Test or Inspection
Corrective Action
Malfunction
17.
Select Exit and then select
Yes. (Volume 3, WP 0340)
18.
Select Reading and select
Disconnect From Model(s).
(Volume 3, WP 0340)
19.
Select Yes to terminate your
readings connection. (Volume
3, WP 0340)
20.
Turn key switch to OFF
position for a minimum of 90
seconds to complete the
calibration. (TM
5-3805-294-10). (Volume 5,
WP 0794)
21.
Clear and refresh DTCs. Note
1.
If DTC 652.13 is still an active
if DTC 652.13 is still an active
DTC, it is possible that another
fault exists or that another
DTC. (Volume 3, WP 0362)
troubleshooting procedure
applies. If this was the first time
through this procedure, restart
procedure at Malfunction 1.
If DTC 652.13 is not an active
2.
DTC, problem corrected.
1.
Turn key switch to ON position,
3.
Re-enter Injector
but DO NOT START ENGINE
Data.
(TM 5-3805-294-10). (Volume
5, WP 0794).
2.
Select Readings and select
Connect to Model(s). (Volume
3, WP 0340)
3.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0340)
4.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0340)
5.
tab in Service ADVISOR and
select 240DLCR - Excavator -
None. (Volume 3, WP 0340)
0074-5