• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 898.09 - Engine Speed Request Not Received or Timed Out - Continued
Table 1. DTC 898.09 - Engine Speed Request Not Received or Timed Out - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  642    643    644    645    646  647  648    649    650    651    652  
img
TM 5-3805-294-23-1
0095
Table 1. DTC 898.09 - Engine Speed Request Not Received or Timed Out - Continued.
Test or Inspection
Corrective Action
Malfunction
Measure resistance (Volume
1.
If continuity is present, replace
34.
Short Circuit
monitor controller wiring
Between Connector
3, WP 0369) between
harness. (Volume 4,
X20 Socket 7 and
connector X20 socket 7
Socket 11.
WP 0519) Restore machine to
(Volume 5, WP 0800, Figure
original condition. Clear and
87) and connector X20 socket
refresh DTCs. (Volume 3,
11. Note reading.
WP 0362)
2.
If continuity is not present,
proceed to Malfunction 35.
Measure resistance (Volume
1.
If continuity is present, replace
35.
Short Circuit
monitor controller wiring
Between Connector
3, WP 0369) between
harness. (Volume 4,
X20 Socket 6 and
connector X20 socket 6 and
Socket 11.
connector X20 socket 11.
WP 0519) Restore machine to
original condition. Clear and
(Volume 5, WP 0800, Figure
refresh DTCs. (Volume 3,
87) Note reading.
WP 0362)
2.
If continuity is not present,
proceed to Malfunction 36.
Measure resistance (Volume
1.
If continuity is present, replace
36.
Short Circuit
cab wiring harness. (Volume 4,
Between Connector
3, WP 0369) between
X30 Socket 4 and
connector X30 socket 4
WP 0504) Restore machine to
Connector X28
original condition. Clear and
(Volume 5, WP 0800, Figure
Sockets 1 and 12.
refresh DTCs. (Volume 3,
96) and connector X28 sockets
WP 0362)
1 and 12. (Volume 5,
WP 0800, Figure 94) Note
2.
If continuity is not present,
readings.
proceed to Malfunction 37.
Measure resistance (Volume
1.
If continuity is present, replace
37.
Short Circuit
cab wiring harness. (Volume 4,
Between Connector
3, WP 0369) between
X30 Socket 4 and
connector X30 socket 4
WP 0504) Restore machine to
Connector X29
original condition. Clear and
(Volume 5, WP 0800, Figure
Sockets 7 and 17.
refresh DTCs. (Volume 3,
96) and connector X29 sockets
7 and 17. (Volume 5,
WP 0362)
WP 0800, Figure 95) Note
2.
If continuity is not present,
readings.
proceed to Malfunction 38.
Measure resistance (Volume
1.
If continuity is present, replace
38.
Short Circuit
cab wiring harness. (Volume 4,
Between Connector
3, WP 0369) between
X30 Socket 15 and
connector X30 socket 15
WP 0504) Restore machine to
Connector X28
original condition. Clear and
(Volume 5, WP 0800, Figure
Sockets 1 and 12.
refresh DTCs. (Volume 3,
96) and connector X28 sockets
1 and 12. (Volume 5,
WP 0362)
WP 0800, Figure 94) Note
If continuity is not present,
2.
readings.
proceed to Malfunction 39.
0095-13


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.