Table 1. DTC 1172.03 - Compressor Inlet Temperature Signal Out of Range High - Continued
DTC 1172.04 - COMPRESSOR INLET TEMPERATURE SIGNAL OUT OF RANGE LOW

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  665    666    667    668    669  670  671    672    673    674    675  
img
TM 5-3805-294-23-1
0098
Table 1. DTC 1172.03 - Compressor Inlet Temperature Signal Out of Range High - Continued.
Test or Inspection
Corrective Action
Malfunction
5.
Turn key switch to OFF
1.
If DTC 1172.03 is still active, it
position. (TM 5-3805-294-10)
is possible that another fault
exists or that another
(Volume 5, WP 0794)
troubleshooting procedure
applies. If this was the first time
through this procedure, restart
procedure at Malfunction 1.
2.
If DTC 1172.03 is not active,
problem corrected. Restore
machine to original condition.
END OF WORK PACKAGE