Table 1. DTC 1172.04 - Compressor Inlet Temperature Signal Out of Range Low - Continued
Table 1. DTC 1172.04 - Compressor Inlet Temperature Signal Out of Range Low - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  674    675    676    677    678  679  680    681    682    683    684  
img
TM 5-3805-294-23-1
0099
Table 1. DTC 1172.04 - Compressor Inlet Temperature Signal Out of Range Low - Continued.
Test or Inspection
Corrective Action
Malfunction
11.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
12.
Turn key switch to OFF
1.
If voltage fluctuated, replace
position (TM 5-3805-294-10).
engine wiring harness.
(Volume 5, WP 0794)
(Volume 4, WP 0510) Restore
machine to original condition
and perform Harness
Diagnostic Mode Test.
(Volume 3, WP 0345)
2.
If voltage did not fluctuate,
proceed to Malfunction 16.
1.
Turn key switch to ON position,
16.
Check DTC 1172.04
but DO NOT START ENGINE
For Active Status.
(TM 5-3805-294-10). (Volume
5, WP 0794)
2.
Refresh DTCs. Note if DTC
1172.04 is still an active DTC.
(Volume 3, WP 0362)
3.
Turn key switch to OFF
1.
If DTC 1172.04 is still an active
position (TM 5-3805-294-10).
DTC, problem was not found
and may have been missed
(Volume 5, WP 0794)
during troubleshooting.
Restart procedure at
Malfunction 1.
2.
If DTC 1172.04 is not an active
DTC, problem corrected.
1.
Replace ECU. (Volume 4,
17.
ECU is Faulty.
WP 0508)
2.
Reconnect all connectors.
3.
Turn key switch to ON position,
but DO NOT START ENGINE
(TM 5-3805-294-10). (Volume
5, WP 0794)
4.
Refresh DTCs. Note if DTC
1172.04 is still an active DTC.
(Volume 3, WP 0362)
0099-9