Table 1. Excessive Fuel Consumption - Continued
Table 1. Excessive Fuel Consumption - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  858    859    860    861    862  863  864    865    866    867    868  
img
TM 5-3805-294-23-1
0125
Table 1. Excessive Fuel Consumption - Continued.
Test or Inspection
Corrective Action
Malfunction
Perform Cylinder
1.
If compression test is within
10.
Mechanical Gauge
Compression Test With
limits, proceed to Malfunction
Cylinder
11.
Compression Test.
Gauge. (Volume 3, WP 0328)
Note readings.
2.
If pressure is too low, replace
cylinder head. (Volume 3,
WP 0407) Restore machine to
original condition.
3.
If pressure is too high, replace
engine. (Volume 3, WP 0410)
Restore machine to original
condition.
1.
Start engine (TM
11.
Fuel Lines Leaking.
5-3805-294-10). (Volume 5,
WP 0794)
2.
Set engine speed and load to
maximum point, if possible.
3.
Inspect all fuel lines and fittings
for leakage.
0125-4