TM 5-2420-230-24-1
Table 3-6. Unit Troubleshooting Table. -- Continued
Malfunction
Test or Inspection
Corrective Action
TURBOCHARGER EXCESSIVELY NOISY OR VIBRATES OR OIL DRIPPING FROM
TURBOCHARGER ADAPTER. -- CONTINUED
Degreasing Solvent (MIL-PRF-680) is toxic and flammable. Keep away from heat or flame.
Never smoke when using solvent. The flashpoint for Type II Degreasing Solvent is 141 F
(61 C). Wear protective goggles, face shield, and gloves; use only in a well-ventilated area;
avoid contact with skin, eyes, and clothes; and do not breathe vapors. Failure to comply may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
Adhesives, solvents, and sealing compounds burn easily and give off vapors that are harmful to
the skin and clothing. To avoid injury or death, keep away from open fire when using these
materials, and use only in well-ventilated areas. If adhesives, solvents, or sealing compounds
contact the skin or clothing, wash immediately with soap and water, and rinse thoroughly. Failure
to comply may result in injury or death to personnel.
Step 3.
Check air intake (4) on turbocharger (5) for clogging.
If air intake (4) is clogged, clean using degreasing solvent (Item 58, Appendix C) and a clean cloth
Step 4.
Check oil return line (6) on turbocharger (5) for carbon buildup.
If oil return line (6) has carbon buildup, remove and clean using degreasing solvent and a clean cloth.
Change 1