TM 5-2420-230-24-1
12.
Remove the attaching bolts from the bearing
cap and turn the input shaft to free the bear-
ing cap assembly from the housing
(Figure 97).
CAUTION
After the bearing cap assembly is free from
the housing, keep the shaft stationary.
Binding of the shaft and shaft damage may
occur if the shaft is removed at this time.
Figure 97
13.
Carefully slide the piston and bearing cap
assembly from the housing bore until the ball
guide retainer is located (Figure 98).
Figure 98
CAUTION
The ball guide retainer must be held in place
while removing the piston. If not, the ball
return guides and steel balls will drop out of
the assembly. Loss of the steel balls may
occur.
K-78