TM 5-2420-230-24-2
Section 5 - Fuel System - Group 05
Injection Pump Repairs (5-21)
B Series Shop Manual
Page 5-55
Solenoid Voltage Check
with the wiring circuit to the solenoid.
To perform the solenoid voltage check, connect the wiring
harness and apply voltage to the solenoid with the ignition
key as follows:
1. With the key in the run position, check the voltage
hold-in.
2. With the shut down lever held in the shut down posi-
tion, move the key to the start position and check the
pull-in voltage.
Battery
Min Voltage
Voltage
Pull-In
Hold-In
12
6.5
4.0
24
13.0
8.0
L-353