Pressure Relief Valve and Sealing Washer Replacement, Bosch P7100 (5-29) - Continued
Fuel Shut Off Solenoid Replacement, Bosch P7100 (5-32)

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  342    343    344    345    346  347  348    349    350    351    352  
img
TM 5-2420-230-24-2
Injection Pump Repairs (5-21)
Section 5 - Fuel System - Group 05
Page 5-50
B Series Shop Manual
19 mm
Install the pressure relief valve, jump-over tube, and seal-
ing washers in the reverse order of removal.
Seal Replacement, Bosch P7100 (5-30)
Item
Type of Seal
A
O-Ring Seal
B
Sealing Washer
C
Sealing Washers
(Rubber Coated)
Fuel Inlet Banjo Connector Replacement,
Bosch P7100 (5-31)
19 mm
Remove the fuel inlet banjo connector and sealing
washers.
Thoroughly flush the inlet connector with a cleaning so-
lution to ensure it is not blocked with foreign debris.
Replace the fuel inlet banjo connector if the threads are
ruined.