TM 5-2420-230-24-2
Injection Pump Repairs (5-21)
Section 5 - Fuel System - Group 05
Page 5-52
B Series Shop Manual
Move the shut off lever by hand to the full run position.
10 mm, 16 mm
Adjust the solenoid linkage to dimension A. Dimension A
is measured from the bottom surface of the solenoid
mounting bracket to the top of the pivot pin. When prop-
erly adjusted the plunger is magnetically held in with the
shut off lever in the absolute full run position. Turn the
large hex on the end of the plunger to make adjustments.
Solenoid Run Dimension
A = 66.9 mm [2.6 in]
Fuel Shut Off Solenoid Bracket Replacement,
Bosch P7100 (5-34)
Preparatory Step:
Remove shut off solenoid.
8 mm, 5mm Allen
Remove and replace the bracket as illustrated.
Top Capscrews (2)
7 Nm [5 ft-lb]
Side Capscrew (1) 10 Nm [7.4 ft-lb]
Fuel Pump Shut Off Lever Replacement,
Bosch P7100 (5-35)
Preparatory Step:
Remove the shut off solenoid.
L-350