Fuel Shut Off Solenoid Replacement, Bosch P7100 (5-32)
Throttle Lever Replacement, Bosch P7100

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  344    345    346    347    348  349  350    351    352    353    354  
img
TM 5-2420-230-24-2
Injection Pump Repairs (5-21)
Section 5 - Fuel System - Group 05
Page 5-52
B Series Shop Manual
Move the shut off lever by hand to the full run position.
10 mm, 16 mm
Adjust the solenoid linkage to dimension A. Dimension A
is measured from the bottom surface of the solenoid
mounting bracket to the top of the pivot pin. When prop-
erly adjusted the plunger is magnetically held in with the
shut off lever in the absolute full run position. Turn the
large hex on the end of the plunger to make adjustments.
Solenoid Run Dimension
A = 66.9 mm [2.6 in]
Fuel Shut Off Solenoid Bracket Replacement,
Bosch P7100 (5-34)
Preparatory Step:
Remove shut off solenoid.
8 mm, 5mm Allen
Remove and replace the bracket as illustrated.
Torque Value:
Top Capscrews (2)
7 Nm [5 ft-lb]
Side Capscrew (1) 10 Nm [7.4 ft-lb]
Fuel Pump Shut Off Lever Replacement,
Bosch P7100 (5-35)
Preparatory Step:
Remove the shut off solenoid.