• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Engine Run-in (Chassis Dynamometer)
Off-Highway Applications

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  1286    1287    1288    1289    1290  1291  1292    1293    1294    1295    1296  
img
TM 5-2420-230-24-2
Engine Run-in (Without Dynamometer) (014-004)
B3.9 and B5.9 Series Engines
Page 14-10
Section 14 - Engine Testing - Group 14
Operate the engine at torque peak rpm and full load for 4
minutes. Check the gauges and record the readings.
NOTE: Refer to the engine data sheet for the torque peak
rpm of the engine model being tested.
Operate the engine at rated speed (rpm) and full load for
4 minutes. Check the gauges, and record the readings.
Compare the readings to those published on the appro-
priate engine data sheet.
CAUTION
Do not shut off the engine immediately after the run-in
is completed. Allow the engine to cool by operating it
at low idle for a minimum of 3 minutes to avoid internal
component damage.
Make sure all instrumentation is removed before removing
the vehicle from the dynamometer.
Engine Run-in (Without
Dynamometer) (014-004)
Test (014-004-012)
On-Highway Applications
NOTE: Refer to General Engine Test Procedures (Chassis
Dynamometer) (Procedure 014-005) before operating the
engine to avoid internal component damage.
Operate the engine at 1500 to 1800 rpm in high gear for the
first 80 to 160 km [50 to 100 mi] after rebuild.
L-1308