Maintenance--Every 10 Hours or Daily
CHECK HYDRAULIC OIL LEVEL

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  191    192    193    194    195  196  197    198    199    200    201  
img
TM 5-3805-280-10
Maintenance--Every 10 Hours or Daily
CHECK RECOVERY TANK COOLANT LEVEL
With the engine cold, coolant level must be at the FULL
mark on the recovery tank (A).
If coolant is below the FULL mark, add coolant to the
recovery tank.
CAUTION: Prevent possible injury from hot
spraying water. DO NOT remove radiator filler
cap unless engine is cool. Then turn cap slowly
to the stop. Release all pressure before you
remove cap.
If recovery tank is empty, check for leaks. Repair as
required. Add coolant to the radiator and the recovery
tank.
NOTE: If recovery tank is full and radiator is low, check
for leaks in radiator cap and hose connections
between radiator and coolant recovery tank.
Coolant level must be at bottom of the filler neck.
TX,60,DH5566
1917SEP961/1