CHECK HYDRAULIC OIL LEVEL
CHECK HYDRAULIC OIL LEVEL - Continued

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  193    194    195    196    197  198  199    200    201    202    203  
img
TM 5-3805-280-10
Maintenance--Every 10 Hours or Daily
CAUTION: High pressure release of oil from
pressurized system can cause serious burns or
penetrating injury. The hydraulic tank is
pressurized. Do not remove vent plug (A).
Release pressure by loosening vent plug.
11. Loosen vent plug (A) to release hydraulic pressure.
TX,60,DH5096
1908JUL963/5
12. Insert 4 mm (0.15 in.) hex wrench (D) into hole (E)
and turn counterclockwise.
13. Slowly turn cap (A) counterclockwise. Remove cap.
14. Add oil. (See Fuels and Lubricants chapter.)
15. Install cap to case assembly (C) by aligning marks (B)
and turning cap clockwise to lock position.
A--Cap
B--Aligning Marks
C--Case Assembly
D--Hex Wrench
E--Hole
Continued on next page
TX,60,DH5096
1908JUL964/5
12-4