REPLACE HYDRAULIC OIL FILTER - Continued
CHAPTER 16. MAINTENANCE--EVERY 1000 HOURS

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  218    219    220    221    222  223  224    225    226    227    228  
img
TM 5-3805-280-10
Maintenance--Every 500 Hours
ADD COOLANT CONDITIONER TO
RADIATOR
Coolant conditioner prevents rust, scale, and liner
cavitation.
CAUTION: Prevent possible injury from hot
spraying water. Do not remove radiator cap
unless the engine is cool.
Turn cap slowly to the stop to release air to
relieve pressure before removing cap.
1. Turn cap slowly to the stop to release pressure. Then
remove radiator cap.
2. Add TY16004 John Deere Coolant Conditioner or
equivalent non-chromate conditioner/rust inhibitor,
following instructions on container.
Cooling System--Specification
Capacity...................................................................... Approx. 22 L (6 gal)
NOTE: Check coolant every 500 hours or 6 months, or if
you replace 1/3 or more of coolant.
John Deere Liquid Coolant Conditioner does not
protect against freezing.