CHECKING ELECTROLYTE SPECIFIC GRAVITY
REPLACING BATTERIES

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  268    269    270    271    272  273  274    275    276    277    278  
img
TM 5-3805-280-10
Maintenance
See your John Deere dealer for JT05460 SERVICEGARD
battery and coolant tester. Follow directions included with
the tester.
A fully charged battery will have a corrected specific
gravity reading of 1.260. If the reading is below 1.200,
charge the battery.
NOTE: In tropical areas, use 1.225 for the full charge
reading. In cold areas, use 1.280 for the
full-charge reading.
04T,90,FF20 1912MAY932/2
USING BATTERY CHARGER
CAUTION: Disconnect battery ground before
you charge batteries in the machine to prevent
damage to electrical components.
A battery may explode if charged when it is
frozen. Warm battery to 16C (60F) before
charging.
A battery charger may be used as a booster to start
engine.
IMPORTANT: Do not use battery charger as a booster
if a battery has a 1.150 specific gravity
reading or lower. Turn off charger
before connecting or disconnecting it.
T82,EXMA,G
1903AUG921/1
20-6