ADDING 12--VOLT ACCESSORIES
FUSE (BLADE-TYPE) COLOR CODES

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  272    273    274    275    276  277  278    279    280    281    282  
img
TM 5-3805-280-10
Maintenance
IMPORTANT: Install fuse with correct amperage
rating to prevent electrical system
damage from overload.
1--5 Amp--Back up
2--10 Amp--Controller
3--10 Amp--EC Motor
4--5 Amp--Solenoid
5--10 Amp--Pow. on
6--5 Amp--Sw box
7--5 Amp
8--10 Amp
9--5 Amp
10--5 Amp--Travel
11--20 Amp--Lamp
12--10 Amp--Wiper
13--20 Amp--Heater
14--5 Amp--Air con
15--10 Amp--Horn
16--5 Amp--Radio
17--10 Amp--Lighter
18--5 Amp--Room Lamp
19--10 Amp--Auxiliary
20--20 Amp--Lamp
TX,90,DH5331
1926NOV962/2
20-10