POWER CIRCUIT DIAGNOSTIC PROCEDURES - CONTINUED
CHARGING CIRCUIT OPERATIONAL INFORMATION

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  203    204    205    206    207  208  209    210    211    212    213  
img
TM 5-3805-280-24-1
Sub-System Diagnostics
FUSE CHECK
YES: Fuse is OK
NO: Replace fuse.
T7468AF UN14MAR91
9015
Remove cover from fuse block.
15
7
Turn key switch ON.
Connect black (-) probe of multimeter to screw head (ground) in console.
Set multimeter to measure 24 volts.
Connect multimeter red (+) probe to the outside slot in each fuse.
Is 24 volts measured on each fuse?