TM 5-3805-280-24-1
Sub-System Diagnostics
NOTE: A diode can fail in two modes, either shorted or open. Continuity will be
START RELAY COIL
YES: If continuity is
measured in one direction only in a serviceable diode. Use "diode checking mode" on
SUPPRESSION DIODE
measured in both checks,
meter when checking continuity.
(V9) CHECK
diode has failed in a
shorted mode. Replace.
NO: If continuity is NOT
measured in either check,
diode has failed in an
open mode. Replace.
NO: If continuity is
measured in one check
T118385 UN21NOV98
is OK.
Remove diode from connector.
Is continuity measured?
9015
15
Reverse ohmmeter probes.
19
Is continuity measured?
1/1
YES: Relay is OK. Check
BATTERY RELAY (K14)
S--Relay Coil +24 Volt Terminal
wiring harness.
CHECK
E--Relay Coil Ground Terminal
B--Relay Battery Input Terminal
A--Relay Battery Output Terminal
NO: Relay has failed.
Replace relay.
Disconnect harness from relay. Connect 24 volts to small
terminal S and ground small terminal E. Measure
T8182AK UN03MAR94
Is continuity measured?
1/1
Disconnect fusible link from battery relay.
YES: Fusible link is OK.
60 AMP FUSIBLE LINK
Check wiring harness.
(F22) CHECK
Connect ohmmeter to both ends of fusible link. Measure
NO: Fusible link has
failed. Replace fusible
link.
Is continuity measured?
T109319 UN28APR97
1/1
4-84