TM 5-3805-280-24-1
Tests
JT05800 DIGITAL THERMOMETER
INSTALLATION
SERVICE EQUIPMENT AND TOOLS
JT05800 Digital Thermometer
1. Fasten temperature probe (A) to a bare metal hydraulic
line using a tie band.
2. Wrap temperature probe and line with a shop towel.
A--Temperature Probe
B--Cable
C--JT05800 Digital Thermometer
CED,TX08227,2895
1919NOV971/1
JT02156A DIGITAL PRESSURE AND
TEMPERATURE ANALYZER INSTALLATION
SERVICE EQUIPMENT AND TOOLS
JT02156A Digital Pressure and Temperature Analyzer
9025
25
Use the digital pressure and temperature analyzer (A),
30
and transducers (B) in place of analog gauges and a
separate temperature reader.
Transducers are temperature sensitive. Allow transducer
to warm to system temperature. After transducer is
warmed and no pressure applied, push sensor zero button
A--Digital Pressure and Temperature Analyzer
for one second to set the true zero point.
B--3400 kPa (35 bar) (500 psi) Transducer
--34 000 kPa (350 bar) (5000 psi) Transducer
When using for different pressures, turn selector to OFF
--70 000 kPa (700 bar) (10000 psi) Transducer
for two seconds and then to the pressure range. Readings
are inaccurate if proper range for transducer is not used.
CED,TX08227,2896
1919NOV971/1