REMOVE AND INSTALL WATER MANIFOLD AND THERMOSTATS (DUAL THERMOSTATS)
REMOVE WATER PUMP

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  329    330    331    332    333  334  335    336    337    338    339  
img
TM 5-3805-280-24-2
Cooling System
TEST THERMOSTAT(S)
25
10
Inspect thermostat(s) for debris or damage, and test each
thermostat using an approved testing procedure. See
INSPECT THERMOSTAT AND TEST OPENING
TEMPERATURE in Group 105 for testing procedure and
specifications.
NOTE: Deaeration is accomplished by a jiggle wire or
groove in thermostat flange area (positioned at
top).
RG,25,JW7560
1920NOV971/1
13-333