FUEL SHUT-OFF SOLENOID RESISTANCE TEST (NIPPONDENSO PUMP)
FUEL SHUT-OFF SOLENOID LINKAGE ADJUSTMENT (IN-LINE INJECTION PUMPS)

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  575    576    577    578    579  580  581    582    583    584    585  
img
TM 5-3805-280-24-2
Fuel System Operation and Tests
FUEL SHUT-OFF SOLENOID RESISTANCE
115
53
TEST (LUCAS PUMP)
1. Disconnect wire to solenoid.
2. Remove solenoid noting if plunger is binding in bore.
3. Check coil resistance with ohmmeter. Resistance
should be 9 ohms.
4. Check plunger retraction using a 12 volt source.
Connect positive cable to connector terminal and
negative cable to solenoid body. From the relaxed
position, plunger should retract into the solenoid body
when voltage is applied.
If resistance specification is not met and/or plunger
does not retract, replace solenoid.
DPSG,OUO1004,124
1913MAY981/1
13-580