ROBERT BOSCH STARTING MOTOR SPECIFICATIONS
DIAGNOSING STARTING MOTOR MALFUNCTIONS

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  739    740    741    742    743  744  745    746    747    748    749  
img
TM 5-3805-280-24-2
Robert Bosch Starting Motor Repair
MAKE NO-LOAD TEST
1. Make connections as shown, and use an ammeter (A)
capable of measuring several hundred amps.
60
2. Measure current draw in amps and compare with
10
specifications given earlier in this group.
3
3. If speed and current draw are slightly low, connect a
voltmeter between motor terminal and frame. Observe
voltage during test. Voltage may be reduced because
of high current draw on battery.
A--Ammeter
4. If speed or current draw is significantly different than
B--Battery
specified, diagnose problem per chart which follows.
C--Starter Frame
D--Tachometer
E--Battery Terminal
F--Switch
G--Field Coil Connector
RG,RG34710,2340 1915Mar971/1